===Reset SP from OS=== | |||
<syntaxhighlight lang=bash> | |||
# ipmitool -I bmc bmc reset cold | |||
Sent cold reset command to MC | |||
</syntaxhighlight> | |||
===Access ILOM from OS=== | |||
<syntaxhighlight lang=bash> | |||
# ipmitool sunoem cli | |||
Connected. Use ^D to exit. | |||
-> | |||
</syntaxhighlight> | |||
or | |||
<syntaxhighlight lang=bash> | |||
# ipmitool -I bmc sunoem cli | |||
Connected. Use ^D to exit. | |||
-> | |||
</syntaxhighlight> | |||
===Set SP IP address from OS via ipmitool=== | ===Set SP IP address from OS via ipmitool=== | ||
* Set: | * Set: | ||
< | <syntaxhighlight lang=bash> | ||
# ipmitool lan set 1 ipaddr 172.30.42.149 | # ipmitool lan set 1 ipaddr 172.30.42.149 | ||
Setting LAN IP Address to 172.30.42.149 | Setting LAN IP Address to 172.30.42.149 | ||
Line 13: | Line 33: | ||
# ipmitool lan set 1 defgw ipaddr 172.30.42.1 | # ipmitool lan set 1 defgw ipaddr 172.30.42.1 | ||
Setting LAN Default Gateway IP to 172.30.42.1 | Setting LAN Default Gateway IP to 172.30.42.1 | ||
</ | </syntaxhighlight> | ||
* Check: | * Check: | ||
< | <syntaxhighlight lang=bash> | ||
# ipmitool lan print | # ipmitool lan print | ||
Set in Progress : Commit Write | Set in Progress : Commit Write | ||
Line 42: | Line 62: | ||
: a=ADMIN | : a=ADMIN | ||
: O=OEM | : O=OEM | ||
</ | </syntaxhighlight> | ||
===Restore lost Serial/Product Information=== | ===Restore lost Serial/Product Information=== | ||
< | <syntaxhighlight lang=bash> | ||
$ ssh root@x4100-sp | $ ssh root@x4100-sp | ||
-> show /SYS/MB | -> show /SYS/MB | ||
Line 73: | Line 93: | ||
[(flash)root@X4100-SP:~]# servicetool --board_replaced=mainboard --fru_product_serial_number --fru_chassis_serial_number --fru_product_part_number | [(flash)root@X4100-SP:~]# servicetool --board_replaced=mainboard --fru_product_serial_number --fru_chassis_serial_number --fru_product_part_number | ||
<Fill out the answers> | <Fill out the answers> | ||
</ | </syntaxhighlight> | ||
=SPARC Systeme= | =SPARC Systeme= | ||
==S7-2== | |||
===ILOM=== | |||
<syntaxhighlight lang=bash> | |||
-> set /HOST/bootmode/ script="setenv auto-boot? false" | |||
Set 'script' to 'setenv auto-boot? false' | |||
-> reset /SYS | |||
Are you sure you want to reset /SYS (y/n)? y | |||
Performing reset on /SYS | |||
-> start /HOST/console | |||
Are you sure you want to start /HOST/console (y/n)? y | |||
Serial console started. To stop, type #. | |||
... | |||
SPARC S7-2, No Keyboard | |||
Copyright (c) 1998, 2022, Oracle and/or its affiliates. All rights reserved. | |||
OpenBoot 4.43.9, 126.5000 GB memory installed, Serial #1154xxxxx. | |||
Ethernet address 0:10:e0:xx:xx:xx, Host ID: 86e15f24. | |||
auto-boot? = false | |||
{0} ok | |||
{0} ok printenv boot-device | |||
boot-device = disk net | |||
{0} ok devalias | |||
fallback-miniroot /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1/disk@0 | |||
rcdrom /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1/disk@0 | |||
disk7 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p4 | |||
disk6 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p5 | |||
disk5 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p7 | |||
disk4 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p6 | |||
disk3 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p0 | |||
disk2 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p1 | |||
disk1 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p3 | |||
disk /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p2 | |||
disk0 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p2 | |||
sas0 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0 | |||
sas /pci@300/pci@2/pci@0/pci@14/LSI,sas@0 | |||
nvme3 /pci@300/pci@2/pci@0/pci@7/nvme@0/disk@1 | |||
nvme2 /pci@300/pci@2/pci@0/pci@6/nvme@0/disk@1 | |||
nvme1 /pci@300/pci@2/pci@0/pci@5/nvme@0/disk@1 | |||
nvme0 /pci@300/pci@2/pci@0/pci@4/nvme@0/disk@1 | |||
net3 /pci@300/pci@1/pci@0/pci@1/network@0,3 | |||
net2 /pci@300/pci@1/pci@0/pci@1/network@0,2 | |||
net1 /pci@300/pci@1/pci@0/pci@1/network@0,1 | |||
net /pci@300/pci@1/pci@0/pci@1/network@0 | |||
net0 /pci@300/pci@1/pci@0/pci@1/network@0 | |||
virtual-console | |||
/virtual-devices/console@1 | |||
name aliases | |||
{0} ok boot nvme0 | |||
Boot device: /pci@300/pci@2/pci@0/pci@4/nvme@0/disk@1 File and args: | |||
SunOS Release 5.11 Version 11.4.45.119.2 64-bit | |||
Copyright (c) 1983, 2022, Oracle and/or its affiliates. | |||
Booting to milestone "svc:/milestone/config:default". | |||
/ | |||
</syntaxhighlight> | |||
==T4-1== | |||
===Get disk slot=== | |||
<b>get_disk_slot.sh</b>: | |||
<syntaxhighlight lang=bash> | |||
#!/bin/bash | |||
/usr/sbin/prtconf -v | nawk -v disk="$1" ' | |||
function get_value() { | |||
getline line; | |||
split(line,values,"="); | |||
return values[2]; | |||
} | |||
/inquiry-serial-no/ { | |||
inquiry_serial_no=get_value(); | |||
} | |||
/inquiry-product-id/ { | |||
inquiry_product_id=get_value(); | |||
} | |||
/inquiry-vendor-id/ { | |||
inquiry_vendor_id=get_value(); | |||
} | |||
/obp-path/ { | |||
obp_path=get_value(); | |||
} | |||
/phy-num/ { | |||
phy_num[obp_path]=get_value(); | |||
} | |||
$0 ~ "/dev/rdsk/"disk"$" { | |||
split(obp_path,path_parts,"/"); | |||
if(path_parts[3]=="pci@1"){ | |||
controller[obp_path]=0; | |||
} | |||
if(path_parts[3]=="pci@2"){ | |||
controller[obp_path]=1; | |||
} | |||
printf "%s\n\t%s\n\t%s\n\t%s\n\tcontroller %d, PhyNum %d => Slot %d\n",$1,inquiry_vendor_id,inquiry_serial_no,obp_path,controller[obp_path],phy_num[obp_path],4*controller[obp_path]+phy_num[obp_path] | |||
}' | |||
</syntaxhighlight> | |||
Example: | |||
<syntaxhighlight lang=bash> | |||
# ./get_disk_slot.sh c0t5000C500230D43A3d0 | |||
dev_link=/dev/rdsk/c0t5000C500230D43A3d0 | |||
'SEAGATE' | |||
'00101371ZVHM 3SE1ZVHM' | |||
'/pci@400/pci@2/pci@0/pci@4/scsi@0/disk@w5000c500230d43a1,0' | |||
controller 1, PhyNum 2 => Slot 6 | |||
</syntaxhighlight> | |||
==XSCF== | ==XSCF== | ||
===Set XSCF IP address from OS via ssh through dscp=== | ===Set XSCF IP address from OS via ssh through dscp=== | ||
* Show: | * Show: | ||
< | <syntaxhighlight lang=bash> | ||
# /usr/platform/`uname -i`/sbin/prtdscp | # /usr/platform/`uname -i`/sbin/prtdscp | ||
Domain Address: 192.168.224.2 | Domain Address: 192.168.224.2 | ||
Line 106: | Line 242: | ||
172.42.0.0 * 255.255.0.0 U xscf#0-lan#0 | 172.42.0.0 * 255.255.0.0 U xscf#0-lan#0 | ||
default 172.42.0.1 0.0.0.0 UG xscf#0-lan#0 | default 172.42.0.1 0.0.0.0 UG xscf#0-lan#0 | ||
</ | </syntaxhighlight> | ||
* Delete default gateway: | * Delete default gateway: | ||
< | <syntaxhighlight lang=bash> | ||
XSCF> setroute -c del -n 0.0.0.0 -m 0.0.0.0 -g 172.42.0.1 xscf#0-lan#0 | XSCF> setroute -c del -n 0.0.0.0 -m 0.0.0.0 -g 172.42.0.1 xscf#0-lan#0 | ||
</ | </syntaxhighlight> | ||
* Set: | * Set: | ||
< | <syntaxhighlight lang=bash> | ||
XSCF> setnetwork xscf#0-lan#0 172.32.40.52 -m 255.255.255.0 | XSCF> setnetwork xscf#0-lan#0 172.32.40.52 -m 255.255.255.0 | ||
XSCF> setroute -c add -n 0.0.0.0 -m 0.0.0.0 -g 172.32.40.1 xscf#0-lan#0 | XSCF> setroute -c add -n 0.0.0.0 -m 0.0.0.0 -g 172.32.40.1 xscf#0-lan#0 | ||
Line 143: | Line 279: | ||
XSCF> rebootxscf | XSCF> rebootxscf | ||
The XSCF will be reset. Continue? [y|n] :y | The XSCF will be reset. Continue? [y|n] :y | ||
</ | </syntaxhighlight> | ||
===Enable sending of break signal=== | ===Enable sending of break signal=== | ||
Example on a M10 (Partition 0): | Example on a M10 (Partition 0)... break_signal=off means turn supression of break signals off ;-) : | ||
< | <syntaxhighlight lang=bash> | ||
XSCF> showpparmode -p 0 | XSCF> showpparmode -p 0 | ||
Host-ID :90071f40 | Host-ID :90071f40 | ||
Line 199: | Line 335: | ||
panic[cpu10]/thread=2a100df1c80: Aborting node because pm_tick delay of 13644 ms exceeds 5050 ms | panic[cpu10]/thread=2a100df1c80: Aborting node because pm_tick delay of 13644 ms exceeds 5050 ms | ||
... | ... | ||
</ | </syntaxhighlight> |
Latest revision as of 14:45, 9 January 2023
X86 Systeme
ILOM
Reset SP from OS
# ipmitool -I bmc bmc reset cold
Sent cold reset command to MC
Access ILOM from OS
# ipmitool sunoem cli
Connected. Use ^D to exit.
->
or
# ipmitool -I bmc sunoem cli
Connected. Use ^D to exit.
->
Set SP IP address from OS via ipmitool
- Set:
# ipmitool lan set 1 ipaddr 172.30.42.149
Setting LAN IP Address to 172.30.42.149
# ipmitool lan set 1 netmask 255.255.255.0
Setting LAN Subnet Mask to 255.255.255.0
# ipmitool lan set 1 defgw ipaddr 172.30.42.1
Setting LAN Default Gateway IP to 172.30.42.1
- Check:
# ipmitool lan print
Set in Progress : Commit Write
Auth Type Support : NONE MD2 MD5 PASSWORD
Auth Type Enable : Callback : MD2 MD5 PASSWORD
: User : MD2 MD5 PASSWORD
: Operator : MD2 MD5 PASSWORD
: Admin : MD2 MD5 PASSWORD
: OEM :
IP Address Source : Static Address
IP Address : 172.30.42.149
Subnet Mask : 255.255.255.0
MAC Address : 00:1c:24:f0:70:b0
SNMP Community String : public
IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10
Default Gateway IP : 172.30.42.1
Default Gateway MAC : ff:ff:ff:ff:ff:ff
Backup Gateway IP : 255.255.255.255
Backup Gateway MAC : ff:ff:ff:ff:ff:ff
Cipher Suite Priv Max : aaaaaaaaaaaaaaa
: X=Cipher Suite Unused
: c=CALLBACK
: u=USER
: o=OPERATOR
: a=ADMIN
: O=OEM
Restore lost Serial/Product Information
$ ssh root@x4100-sp
-> show /SYS/MB
/SYS/MB
...
Properties:
type = Motherboard
chassis_name = SUN FIRE X4100
chassis_part_number = 541-0250-04
chassis_serial_number = 0000000-0000000000
chassis_manufacturer = SUN MICROSYSTEMS
product_name = SUN FIRE X4100
product_part_number = 602-0000-00
product_serial_number = 0000000000
product_version = (none)
product_manufacturer = SUN MICROSYSTEMS
fru_name = ASSY,MOTHERBOARD,A64
fru_manufacturer = SUN MICROSYSTEMS
fru_part_number = 501-7644-01
fru_serial_number = 1762TH1-0627002296
...
-> exit
$ ssh sunservice@x4100-sp
Password: <the root password>
[(flash)root@X4100-SP:~]# servicetool --board_replaced=mainboard --fru_product_serial_number --fru_chassis_serial_number --fru_product_part_number
<Fill out the answers>
SPARC Systeme
S7-2
ILOM
-> set /HOST/bootmode/ script="setenv auto-boot? false"
Set 'script' to 'setenv auto-boot? false'
-> reset /SYS
Are you sure you want to reset /SYS (y/n)? y
Performing reset on /SYS
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
Serial console started. To stop, type #.
...
SPARC S7-2, No Keyboard
Copyright (c) 1998, 2022, Oracle and/or its affiliates. All rights reserved.
OpenBoot 4.43.9, 126.5000 GB memory installed, Serial #1154xxxxx.
Ethernet address 0:10:e0:xx:xx:xx, Host ID: 86e15f24.
auto-boot? = false
{0} ok
{0} ok printenv boot-device
boot-device = disk net
{0} ok devalias
fallback-miniroot /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1/disk@0
rcdrom /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1/disk@0
disk7 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p4
disk6 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p5
disk5 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p7
disk4 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p6
disk3 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p0
disk2 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p1
disk1 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p3
disk /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p2
disk0 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0/disk@p2
sas0 /pci@300/pci@2/pci@0/pci@14/LSI,sas@0
sas /pci@300/pci@2/pci@0/pci@14/LSI,sas@0
nvme3 /pci@300/pci@2/pci@0/pci@7/nvme@0/disk@1
nvme2 /pci@300/pci@2/pci@0/pci@6/nvme@0/disk@1
nvme1 /pci@300/pci@2/pci@0/pci@5/nvme@0/disk@1
nvme0 /pci@300/pci@2/pci@0/pci@4/nvme@0/disk@1
net3 /pci@300/pci@1/pci@0/pci@1/network@0,3
net2 /pci@300/pci@1/pci@0/pci@1/network@0,2
net1 /pci@300/pci@1/pci@0/pci@1/network@0,1
net /pci@300/pci@1/pci@0/pci@1/network@0
net0 /pci@300/pci@1/pci@0/pci@1/network@0
virtual-console
/virtual-devices/console@1
name aliases
{0} ok boot nvme0
Boot device: /pci@300/pci@2/pci@0/pci@4/nvme@0/disk@1 File and args:
SunOS Release 5.11 Version 11.4.45.119.2 64-bit
Copyright (c) 1983, 2022, Oracle and/or its affiliates.
Booting to milestone "svc:/milestone/config:default".
/
T4-1
Get disk slot
get_disk_slot.sh:
#!/bin/bash
/usr/sbin/prtconf -v | nawk -v disk="$1" '
function get_value() {
getline line;
split(line,values,"=");
return values[2];
}
/inquiry-serial-no/ {
inquiry_serial_no=get_value();
}
/inquiry-product-id/ {
inquiry_product_id=get_value();
}
/inquiry-vendor-id/ {
inquiry_vendor_id=get_value();
}
/obp-path/ {
obp_path=get_value();
}
/phy-num/ {
phy_num[obp_path]=get_value();
}
$0 ~ "/dev/rdsk/"disk"$" {
split(obp_path,path_parts,"/");
if(path_parts[3]=="pci@1"){
controller[obp_path]=0;
}
if(path_parts[3]=="pci@2"){
controller[obp_path]=1;
}
printf "%s\n\t%s\n\t%s\n\t%s\n\tcontroller %d, PhyNum %d => Slot %d\n",$1,inquiry_vendor_id,inquiry_serial_no,obp_path,controller[obp_path],phy_num[obp_path],4*controller[obp_path]+phy_num[obp_path]
}'
Example:
# ./get_disk_slot.sh c0t5000C500230D43A3d0
dev_link=/dev/rdsk/c0t5000C500230D43A3d0
'SEAGATE'
'00101371ZVHM 3SE1ZVHM'
'/pci@400/pci@2/pci@0/pci@4/scsi@0/disk@w5000c500230d43a1,0'
controller 1, PhyNum 2 => Slot 6
XSCF
Set XSCF IP address from OS via ssh through dscp
- Show:
# /usr/platform/`uname -i`/sbin/prtdscp
Domain Address: 192.168.224.2
SP Address: 192.168.224.1
# ssh eis-installer@192.168.224.1
XSCF> shownetwork -a
xscf#0-lan#0
Link encap:Ethernet HWaddr 00:0B:5D:E3:D8:C4
inet addr:172.42.0.120 Bcast:172.42.0.255 Mask:255.255.255.0
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:885919090 errors:0 dropped:0 overruns:0 frame:0
TX packets:7150700 errors:1 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:1987024183 (1.8 GiB) TX bytes:492148426 (469.3 MiB)
Base address:0xe000
xscf#0-lan#1
Link encap:Ethernet HWaddr 00:0B:5D:E3:D8:C5
BROADCAST MULTICAST MTU:1500 Metric:1
RX packets:0 errors:0 dropped:0 overruns:0 frame:0
TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
collisions:0 txqueuelen:1000
RX bytes:0 (0.0 B) TX bytes:0 (0.0 B)
Base address:0xc000
XSCF> showroute -a
Destination Gateway Netmask Flags Interface
172.42.0.0 * 255.255.0.0 U xscf#0-lan#0
default 172.42.0.1 0.0.0.0 UG xscf#0-lan#0
- Delete default gateway:
XSCF> setroute -c del -n 0.0.0.0 -m 0.0.0.0 -g 172.42.0.1 xscf#0-lan#0
- Set:
XSCF> setnetwork xscf#0-lan#0 172.32.40.52 -m 255.255.255.0
XSCF> setroute -c add -n 0.0.0.0 -m 0.0.0.0 -g 172.32.40.1 xscf#0-lan#0
XSCF> applynetwork
The following network settings will be applied:
xscf#0 hostname :hfgsun07-xsfc
DNS domain name :intern.hfg-inkasso.de
nameserver :172.41.0.2
interface :xscf#0-lan#0
status :up
IP address :172.32.40.52
netmask :255.255.255.0
route :-n 172.32.40.1 -m 255.255.255.255
route :-n 0.0.0.0 -m 0.0.0.0 -g 172.32.40.1
interface :xscf#0-lan#1
status :down
IP address :
netmask :
route :
Continue? [y|n] :y
Please reset the XSCF by rebootxscf to apply the network settings.
Please confirm that the settings have been applied by executing
showhostname, shownetwork, showroute and shownameserver after rebooting
the XSCF.
XSCF> rebootxscf
The XSCF will be reset. Continue? [y|n] :y
Enable sending of break signal
Example on a M10 (Partition 0)... break_signal=off means turn supression of break signals off ;-) :
XSCF> showpparmode -p 0
Host-ID :90071f40
Diagnostic Level :max
Message Level :max
Alive Check :on
Watchdog Reaction :reset
Break Signal :on
Autoboot(Guest Domain) :on
Elastic Mode :off
IOreconfigure :false
CPU Mode :auto
PPAR DR(Current) :off
PPAR DR(Next) :off
XSCF> setpparmode -p 0 -m break_signal=off
Diagnostic Level :max -> -
Message Level :max -> -
Alive Check :on -> -
Watchdog Reaction :reset -> -
Break Signal :on -> off
Autoboot(Guest Domain) :on -> -
Elastic Mode :off -> -
IOreconfigure :false -> -
CPU Mode :auto -> -
PPAR DR :off -> -
The specified modes will be changed.
Continue? [y|n] :y
configured.
Diagnostic Level :max
Message Level :max
Alive Check :on (alive check:available)
Watchdog Reaction :reset (watchdog reaction:reset)
Break Signal :off (break signal:send)
Autoboot(Guest Domain) :on
Elastic Mode :off
IOreconfigure :false
CPU Mode :auto
PPAR DR :off
XSCF> sendbreak -y -p0
Send break signal to PPAR-ID 0?[y|n] :y
XSCF> console -y -p0
Console contents may be logged.
Connect to PPAR-ID 0?[y|n] :y
c)ontinue, s)ync, r)eset? c
^@Notifying cluster that this node is panicking
panic[cpu10]/thread=2a100df1c80: Aborting node because pm_tick delay of 13644 ms exceeds 5050 ms
...