=StorageTek SL150 Modular Tapelibrary= | =StorageTek SL150 Modular Tapelibrary= | ||
Line 4: | Line 5: | ||
===Default Password=== | ===Default Password=== | ||
passw0rd | passw0rd | ||
===Solaris Configuration=== | |||
To use the Ultrium-6 Tape drives with Solaris you have to put the following into your st.conf: | |||
<syntaxhighlight lang=bash> | |||
tape-config-list = | |||
"HP Ultrium 6-SCSI ","HP Ultrium 6-SCSI","HP Ultrium 6","HP Ultrium LTO 6","HP_LTO_GEN_6"; | |||
HP_LTO_GEN_6 = 2,0x3B,0,0x18659,4,0x00,0x46,0x58,0x5A,3,60,1200,600,1200,600,600,18000 | |||
</syntaxhighlight> | |||
The vendor string has to be exactly 8 characters: | |||
HP<6 spaces>Product... | |||
Unload the st driver after changing the st.conf: | |||
<syntaxhighlight lang=bash> | |||
# modunload -i $(modinfo | nawk '$6=="st"{print $1}') | |||
</syntaxhighlight> | |||
Check if the new config settings matched the drive: | |||
<syntaxhighlight lang=bash> | |||
# mt -f /dev/rmt/0cn config | |||
"HP Ultrium 6-SCSI", "HP Ultrium 6-SCSI ", "CFGHPULTRIUM6SCSI"; | |||
CFGHPULTRIUM6SCSI = 2,0x3B,0,0x18619,4,0x58,0x58,0x5A,0x5A,3,60,1200,600,1200,600,600,18000; | |||
</syntaxhighlight> | |||
==General Documentation== | ==General Documentation== |
Latest revision as of 05:10, 26 November 2021
StorageTek SL150 Modular Tapelibrary
General Knowledge
Default Password
passw0rd
Solaris Configuration
To use the Ultrium-6 Tape drives with Solaris you have to put the following into your st.conf:
tape-config-list =
"HP Ultrium 6-SCSI ","HP Ultrium 6-SCSI","HP Ultrium 6","HP Ultrium LTO 6","HP_LTO_GEN_6";
HP_LTO_GEN_6 = 2,0x3B,0,0x18659,4,0x00,0x46,0x58,0x5A,3,60,1200,600,1200,600,600,18000
The vendor string has to be exactly 8 characters: HP<6 spaces>Product...
Unload the st driver after changing the st.conf:
# modunload -i $(modinfo | nawk '$6=="st"{print $1}')
Check if the new config settings matched the drive:
# mt -f /dev/rmt/0cn config
"HP Ultrium 6-SCSI", "HP Ultrium 6-SCSI ", "CFGHPULTRIUM6SCSI";
CFGHPULTRIUM6SCSI = 2,0x3B,0,0x18619,4,0x58,0x58,0x5A,0x5A,3,60,1200,600,1200,600,600,18000;