ssacli

Install the tool

# echo "deb http://downloads.linux.hpe.com/SDR/downloads/MCP/ubuntu $(lsb_release --short --codename)/current non-free" >> /etc/apt/sources.list.d/hp.list
# curl http://downloads.linux.hpe.com/SDR/hpePublicKey2048_key1.pub | sudo apt-key add -
# apt update && apt install --yes ssacli

Revive formerly failed disk

# lsscsi 
[0:0:0:0]    storage HP       P440ar           2.52  -        
[0:1:0:0]    disk    HP       LOGICAL VOLUME   2.52  /dev/sda 
[0:1:0:1]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdb 
[0:1:0:2]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdc 
[0:1:0:3]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdd 
[0:1:0:5]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdf 
# ssacli ctrl slot=0 ld all show status

   logicaldrive 1 (279.37 GB, RAID 0): OK
   logicaldrive 2 (931.48 GB, RAID 0): OK
   logicaldrive 3 (279.37 GB, RAID 0): OK
   logicaldrive 4 (931.48 GB, RAID 0): OK
   logicaldrive 5 (279.37 GB, RAID 0): Failed
   logicaldrive 6 (931.48 GB, RAID 0): OK

# ssacli ctrl slot=0 ld 5 modify reenable forced
# ssacli ctrl slot=0 ld all show status

   logicaldrive 1 (279.37 GB, RAID 0): OK
   logicaldrive 2 (931.48 GB, RAID 0): OK
   logicaldrive 3 (279.37 GB, RAID 0): OK
   logicaldrive 4 (931.48 GB, RAID 0): OK
   logicaldrive 5 (279.37 GB, RAID 0): OK
   logicaldrive 6 (931.48 GB, RAID 0): OK
# lsscsi 
[0:0:0:0]    storage HP       P440ar           2.52  -        
[0:1:0:0]    disk    HP       LOGICAL VOLUME   2.52  /dev/sda 
[0:1:0:1]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdb 
[0:1:0:2]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdc 
[0:1:0:3]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdd 
[0:1:0:4]    disk    HP       LOGICAL VOLUME   2.52  /dev/sde 
[0:1:0:5]    disk    HP       LOGICAL VOLUME   2.52  /dev/sdf

hpacucli

reenable disk after replacement

[root@app02 ~]# hpacucli ctrl all show config

Smart Array P410i in Slot 0 (Embedded)    (sn: 50014380141236F0)

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (279.4 GB, RAID 0, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)

   array B (SAS, Unused Space: 0  MB)


      logicaldrive 2 (279.4 GB, RAID 0, Failed)

      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)

   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 250 (WWID: 50014380141236FF)

[root@app02 ~]# hpacucli controller slot=0 logicaldrive 2 modify reenable forced
[root@app02 ~]# hpacucli ctrl all show config

Smart Array P410i in Slot 0 (Embedded)    (sn: 50014380141236F0)

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (279.4 GB, RAID 0, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)

   array B (SAS, Unused Space: 0  MB)


      logicaldrive 2 (279.4 GB, RAID 0, OK)

      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)

   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 250 (WWID: 50014380141236FF)